เครื่องดับเพลิงผงแห้งแบบพกพา 1 กิโลกรัม
Cat:เครื่องดับเพลิง DCP/โฟม/น้ำ
เครื่องดับเพลิงแบบพกพาแบบพกพาแบบพกพา 1 กิโลกรัมเป็นอุปกรณ์ความปลอดภัยที่ใช้ในการดับไฟขนาดเล็กในสถานการณ์ฉุกเฉิน เปลือกนอกของมันทำจากเหล็กเพื่อให้คว...
ดูรายละเอียดThe location of Foam Fire Extinguisher is crucial to ensuring it is accessible during an emergency. It should be stored in a high-traffic area that is easily visible and accessible to all building occupants, even in low-light conditions or during times of stress. The extinguisher must be placed in areas with increased fire risk , such as kitchens , storage rooms , laboratories , or warehouses where flammable liquids or combustibles are common. The mounting height should be between 3 to 5 feet from the ground to ensure it’s reachable for most people in an emergency situation, especially if there are individuals with disabilities. For larger facilities, multiple extinguishers should be placed at strategic points , ensuring every area is within a 75-foot (22.8 meters) travel distance from a fire extinguisher, as recommended by safety regulations such as NFPA (National Fire Protection Association) standards. In some instances, signage indicating the presence of the extinguisher can further help guide people toward its location during a crisis.
Foam Fire Extinguishers are sensitive to temperature fluctuations , and extreme conditions can impact their reliability. The temperature range for safe storage is generally between 32°F (0°C) and 120°F (49°C) . Storing the extinguisher outside of this range can cause issues with the foam compound inside. For example, low temperatures can cause the foam solution to freeze , which might prevent the extinguisher from discharging properly when needed. Conversely, high temperatures can lead to increased internal pressure , potentially causing the canister to rupture or the contents to degrade, reducing the overall effectiveness of the extinguisher. For environments with extreme weather conditions (like in cold storage areas or desert climates), consider using temperature-controlled storage to maintain the extinguisher’s integrity or placing the extinguisher in weatherproof enclosures to protect it from temperature extremes.
Foam Fire Extinguishers should be stored in dry, protected areas away from direct sunlight or exposure to moisture. Prolonged exposure to UV radiation from sunlight can cause the external materials of the extinguisher, such as the canister , to weaken, degrade, or become brittle. The foam solution itself is also susceptible to degradation if exposed to intense sunlight or extreme heat . Additionally, moisture can lead to corrosion or rusting, particularly on the metal components of the extinguisher, such as the nozzle and valve mechanism, compromising both the integrity and function of the unit. Ideally, extinguishers should be stored in a weatherproof storage cabinet or a protected indoor environment , ensuring that they remain safe from exposure to outdoor elements, especially in locations prone to heavy rain or humidity.
Proper positioning of the Foam Fire Extinguisher is key to maintaining its functionality and ensuring it is ready for use. The extinguisher should always be stored in an upright position to ensure that the foam solution remains evenly distributed inside the canister. If stored on its side or upside down, the foam agent may settle, causing it to lose its effectiveness. Furthermore, the extinguisher must be securely mounted using wall brackets or mounted on a stand that is firmly anchored to a solid surface. This prevents accidental tipping or falling, which could damage the extinguisher or render it inaccessible during an emergency. The mounting bracket or holder should be appropriate for the weight and design of the extinguisher and allow for quick retrieval when needed. In industrial or warehouse settings, the extinguisher should be mounted in high-traffic areas to facilitate immediate access.
Regular inspections of the Foam Fire Extinguisher are essential to ensuring it remains in good working condition. A visual check should be performed at least once a month to confirm that the gauge reading is in the green zone , indicating that the extinguisher is properly pressurized. Ensure the hose or nozzle is free from blockages or damage, and check for any leaks or signs of corrosion on the metal components. In addition, verify that the pin and tamper seal are intact and that no unauthorized use has occurred. It is important to schedule a full maintenance check annually or as required by local regulations, such as NFPA 10 or OSHA standards , which may require professional inspections. If any issues such as pressure loss , damage , or missing parts are identified, the extinguisher should be repaired or replaced immediately to avoid potential failure during a fire emergency.
To guarantee quick and easy access, Foam Fire Extinguishers should be stored in an area that is free from obstructions or physical barriers. A clear, unobstructed path to the extinguisher is essential in the event of a fire. This is especially important in high-risk areas like kitchens, chemical storage areas, or industrial environments. Ensure the area around the extinguisher is well-lit , and regularly monitor the surroundings to avoid any clutter or equipment being placed in front of it. In environments where high traffic occurs, consider using floor markings or warning signs to maintain a clear zone around the extinguisher and prevent accidental blockage. This ensures that anyone can reach and operate the extinguisher quickly, reducing delays in the critical moments following a fire outbreak.